1) Ενεργοποιούμε το πλυντήριο και το βάζουμε σε κάποιο πρόγραμμα ΕΚΤΟΣ από το 1ο.
2) Κλείνουμε την πόρτα.
3) Κρατάμε πατημένο το START και το πλήκτρο ακριβώς δεξιά του.
4) Μας εμφανίζει νέο κωδικό βλάβης. Ανατρέξτε παρακάτω να τον βρείτε.
E11
|
· Poor fill before wash cycle
· Tap off or water pressure too low
· Drain hose improperly positioned
· Fill valve is defective
· Leaks on pressure switch
· Pressure switch failed
· Wiring fault
· Main board defective
· Cycle is paused with door locked Start
|
E12
|
· Difficulty in fill during drying (maximum time 3 min. fill in drying during the wash load phase)
· Tap off or water pressure too low Valve failed
· Pressure switch water circuit
· Pressure switches
· Wiring
· Main PCB
· Cycle is paused
|
E13
|
· Water leaks Drain hose improperly positioned
· Water pressure too low
· Fill valve is defective
· Water circuit on pressure switch is leaking or blocked
· Pressure switch faulty
· Cycle is paused with door locked
|
E21
|
· Poor draining
· Drain hose kinked/clogged/improperly positioned
· Drain filter clogged/dirty
· Drain pump faulty
· Pressure switch faulty
· Wiring faulty
· Main board faulty
· Current leak between heating element and ground
· Cycle is paused Start
|
E22
|
· Difficulty in fill during drying or drying condenser blocked (pressure switch closed on “FULL”)
· Drain hose kinked
· Filter blocked
· Drying condenser blocked
· Drain pump faulty
· Pressure switches faulty
· Wiring
· Main circuit board faulty
· Current leakage between heater and ground
· Cycle is paused Start
|
E23
|
· Defective triac for drain pump
· Drain pump faulty
· Wiring faulty
· Main board faulty
· Emergency drain procedure – Cycle stops with door unlocked OFF/reset
|
This refers to the triac that controls the pump function on the main controller.
E24
|
· Malfunction in sensing circuit on triac for drain pump
· Main board faulty
· Emergency drain procedure – Cycle stops with door unlocked OFF/reset
|
E31
|
· Malfunction in pressure switch circuit (frequency of signal from pressure switch out of limits) · Pressure switch faulty
· Wiring
· Main PCB faulty
· Cycle stops with door locked OFF/reset
|
E32
|
· Electronic pressure switch improperly calibrated (level on electronic pressure switch differs from 0-66 mm after initial calibration drain and when anti-boiling pressure switch is on “empty”)
· Tap is off or water pressure is too low
· Fill valve faulty
· Water circuit on pressure switches
· Pressure switches
· Wiring
· PCB faulty
· Cycle is paused Start
|
E33
|
· Inconsistency between level on electronic pressure switch and level on anti-boiling pressure switch 1-2 (fault persists for at least 60 sec.)
· Pressure switch defective
· Current leak between heating element and ground
· Heating element
· Wiring faulty
· Main board faulty
· Water circuit
· Emergency drain procedure – Cycle stops with door unlocked OFF/reset
|
E34
|
· Inconsistency between level on electronic pressure switch and level on anti-boiling pressure switch 2 (fault persists for at least 60 sec.)
· Pressure switch faulty
· Electrical current leak between heating element and ground
· Heating element faulty
· Wiring faulty
· Main board faulty
· Water circuit
· Emergency drain procedure – Cycle stops with door unlocked OFF/reset
|
E35
|
· Overflow error
· Fill valve is faulty
· Leaks from water circuit on pressure switch
· Pressure switch defective
· Wiring defective
· Main board defective
· Cycle stops – Emergency drain procedure – Drain pump continues to operate (5 min. on, then 5 min. off, etc.)
· OFF/reset
|
E36
|
· Sensing circuit on anti-boiling pressure switch 1 defective
· Main board faulty
· Cycle stops with door locked OFF/reset
|
As above.
E37
|
· Sensing circuit on anti-boiling pressure switch 2 defective
· Main board faulty
· Cycle stops with door locked OFF/reset
|
As Above
E38
|
· Internal pressure takeoff is blocked (water level does not change for at least 30 sec of drum rotation)
· Water circuit on pressure switches
· Pressure switches
· Motor belt broken
· Heating phase is skipped
|
E39
|
· Defective HV sensing on anti-overflow system
· Main board faulty
· Cycle stops with door locked OFF/reset
|
E3A
|
· Faulty sensing by heating resistance relay
· Main board defective.
· Cycle stops with door locked OFF/reset
|
E41
|
· Door unlocked
· Door lock faulty
· Wiring faulty
· Main board faulty
· Cycle is paused Start
|
Usually a door lock that’s faulty.
E42
|
· Problem closing the door
· Door lock faulty
· Wiring faulty
· Main board faulty
· Cycle is paused Start
|
Close the door!
E43
|
· Defective triac supplying power to door delay system
· Door lock unit faulty
· Wiring faulty
· Main board faulty
· Emergency drain procedure – Cycle stops OFF/reset
|
Pretty much the same as E40 and E41 fault codes.
E44
|
· Defective sensing by door delay system
· Main board faulty
· Emergency drain procedure – Cycle stops OFF/reset
|
E45
|
· Defective sensing by triac on door delay system
· Main board faulty
· Emergency drain procedure – Cycle stops OFF/reset
|
E51
|
· Motor power supply triac short-circuited
· PCB faulty
· Current leakage from motor or from wiring loom
· Cycle blocked, door locked (after 5 attempts) OFF/reset
|
Yet again, this refers to the triac on the electronic controller and not a DIY job.
E52
|
· No signal from motor tachometric generator
· Motor faulty
· Wiring faulty
· PCB faulty
· Cycle blocked, door locked (after 5 attempts) OFF/reset
|
Tacho coil on the motor is most probably faulty. This coil reads a magnet as the motor turns to detect the speed that the motor is spinning at and this in turn allows the electronic controller to set the motor to revolve at different speeds for the various program options.
E53
|
· Motor triac sensing circuit faulty
· PCB faulty
· Cycle blocked, door locked OFF/reset
|
Another one that is a fault being reported on the electronic controller and not a DIY repair.
E54
|
· Motor relay contacts sticking
· PCB faulty
· Current leakage from motor or from wiring
· Cycle blocked, door locked (after 5 attempts) OFF/reset
|
As above.
E61
|
· Insufficient heating during washing
· NTC sensor faulty
· Heating element faulty
· Wiring faulty
· PCB faulty
· The heating phase is skipped
|
Usually a heater failure but possibly the thermostat or NTC temperature sensor or wiring to either.
E62
|
· Overheating during washing
· NTC sensor faulty
· Heating element faulty
· Wiring faulty
· PCB faulty
· Safety drain cycle – Cycle stopped with door open OFF/reset
|
As above only the heater will likely be okay but it is still possible that the wash heater is faulty.
E66
|
· Heating element power relay faulty
· PCB faulty
· Current leakage from heating element to ground
· Safety drain cycle – Cycle stopped with door open OFF/reset
|
Another one that requires an engineer, not a DIY repair.
E71
|
· NTC sensor for wash cycle defective
· Faulty NTC sensor
· Wiring faulty
· Main board faulty
· Heating is skipped revert to Start
|
Self explanatory but do also check the wiring to the temperature probe.
E72
|
· Fault in NTC sensor on drying condenser (voltage out of range = short-circuit, open circuit)
· Drying NTC sensor (condenser) faulty
· Wiring faulty
· Main circuit board faulty
· Heating is skipped revert to Start
|
E73
|
· Fault in NTC sensor on drying duct (voltage out of range = short-circuit, open circuit)
· Drying NTC sensor (duct) faulty
· Wiring faulty
· Main circuit board faulty
· Heating is skipped revert to Start
|
E74
|
· NTC sensor for wash cycle improperly positioned
· NTC sensor incorrectly positioned
· Faulty NTC sensor
· Wiring defective
· Main board faulty
· Heating is skipped revert to Start
|
E82
|
· Error in selector reset position
· PCB faulty (Wrong configuration data)
· Selector, wiring faulty
· OFF/reset
|
Another non-DIY one, you will need an engineer.
E83
|
· Error in reading selector
· PCB faulty (Wrong configuration data)
· Selector, wiring
· Cycle cancelled
|
E84
|
· “Sensing” circuit on circulation pump triac faulty (input signal to processor always 0V or 5V)
· PCB Drain
· Cycle blocked (door open)
· OFF/reset
|
E85
|
· Circulation pump faulty (incongruency between status of “sensing” circuit on circulation pump and status of TRIAC)
· Circulation pump
· Wiring
· Main PCB
· Drain, cycle blocked (door open)
· OFF/reset
|
E91
|
· Communication incongruence between main PCB- display board (versions not compatible)
· Wiring faulty
· Faulty control/display board
· Main PCB faulty
· Cycle interrupted
|
E92
|
· Communication incongruence between main PCB- display board (versions not compatible)
· Wrong control/display board
· Wrong PCB (do not correspond to the model)
· Cycle interrupted
|
E93
|
· Incorrect configuration of appliance
· Incorrect configuration data
· PCB faulty
· Cycle interrupted OFF/reset
|
E94
|
· Incorrect configuration of washing cycle
· Incorrect configuration data
· PCB faulty
· Cycle interrupted OFF/reset
|
E95
|
· Communication error between microprocessor and EEPROM
· PCB faulty
· Cycle interrupted OFF/reset
|
E97
|
· Incongruence between programme selector and cycle configuration
· Faulty PCB (Wrong configuration data)
· Cycle interrupted OFF/reset
|
As above.
EB1
|
· Frequency of appliance incorrect
· Power supply problems (incorrect / disturbance)
· PCB faulty
· Cycle interrupted
|
Check mains supply, you may require an electrician to do this for you.
EB2
|
· Voltage too high Power supply problems (incorrect / disturbance)
· PCB faulty
· Cycle interrupted
|
Check mains supply, you may require an electrician to do this for you.
EB3
|
· Voltage too low
· Power supply problems (incorrect / disturbance)
· PCB faulty
· Cycle interrupted
|
Check mains supply, you may require an electrician to do this for you.
EC1
|
· Solenoid valve inoperative but flow meter operating
· Main board faulty
· Fill valve faulty
· Cycle stops with door locked (after 5 attempts). OFF/reset
|
EC2
|
· Signal from turbidity sensor out of limits
· Turbidity sensor faulty
· Main board faulty
· Wiring faulty
· Start/reset
|
EC3
|
· Signal from weight sensor out of limits
· Weight sensor faulty
· Main board faulty
· Wiring faulty
· Start/reset
|
EF1
|
· Drain filter blocked (too long drain phase)
· Drain tube blocked/kinked/too high
· Drain filter dirty/blocked
· Warning displayed at the end of cycle (specific LED)
|
EF2
|
· Overdosing of detergent (too much foam during drain phases)
· Excessive detergent dosing
· Drain tube kinked/blocked
· Drain filter dirty/blocked
|
EF3
|
· Control water intervention
· Water leakage on the base
· Faulty water control device
· Water drain and cycle blocked OFF/reset
|
EF4
|
· Low pressure of water fill, no signal of flow meter and solenoid open
· Tap closed, low water fill pressure – Reset
|
E00
|
· No alarm
|