Error codes – κλιματιστικά Midea

Error codes – κλιματιστικά Midea , Models: MSC – MSH – MSE – MSG

E0 – EEPROM error / indoor pcb board

E1 – Indoor / outdoor units communication protection / check indoor control board and connection

E2 – Zero-crossing examination error

E3 – Fan speed beyond control

E5 – Open or short circuit of outdoor temperature sensor

E6 – Room temperature or evaporator temperature sensor open or short circuit of

P0 – Module protection – check inverter module and compressor

P1 – Over voltage or too low voltage protection

P2 – Compressor top protection against temperature (Off: 115゜C / On: 100゜C)

P3 – Outdoor low temp. protection. This is optional, factory standard unit has not this function. Unit stops when outdoor temp. is low than -15°C and lasting time more than 60 minutes, and unit runs again when outdoor temp. more than -12°C.

P4 – Inverter compressor drive error



E0 – Πρόβλημα EEPROM  / πλακέτα εσωτερικής

E1 – Πρόβλημα επικοινωνίας εσωτερικής – εξωτερικής μονάδας / έλεγχος καλωδίωσης και πλακετών

E2 – Zero-crossing examination error – Έλεγχος τροφοδοσίας ρεύματος , εσωτερικής πλακέτας

E3 – Ταχύτητα ανεμιστήρα εκτός ελέγχου

E5 – Ανοιχτό ή βραχυκύκλωμα αισθητήρα θερμοκρασίας εξωτερικής μονάδας

E6 – Ανοιχτό ή βραχυκύκλωμα αισθητήρα θερμοκρασίας δωματίου ή αισθητήρα θερμοκρασίας εξατμιστή

P0 – Προστασία μονάδας – ελέγξτε το inverter module και τον συμπιεστή

P1 – Προστασία από υπερβολική τάση ή πολύ χαμηλή τάση

P2 – Προστασία συμπιεστή από θερμοκρασία (Off: 115゜C / On: 100゜C)

P3 – Χαμηλή εξωτερική θερμοκρασία. Η μονάδα σταματά όταν η εξωτερική θερμοκρασία είναι χαμηλότερη από -15 ° C και διαρκεί περισσότερο από 60 λεπτά. Η μονάδα λειτουργεί ξανά όταν η εξωτερική θερμοκρασία είναι πάνω από -12 ° C.

P4 – Σφάλμα εκκίνησης inverter συμπιεστή