Error codes – κωδικοί βλαβών κλιματιστικά Bosch.
Indoor Units: BMS500-AAU009-0AHXXA , BMS500-AAU012-0AHXXA , BMS500-AAU009-1AHXXA , BMS500-AAU012-1AHXXA , BMS500-AAU018-1AHXXA , BMS500-AAU024-1AHXXA .
Outdoor Units: BMS500-AAS009-0CSXXA , BMS500-AAS012-0CSXXA , BMS500-AAS009-1CSXXA , BMS500-AAS012-1CSXXA , BMS500-AAS018-1CSXXA , BMS500-AAS024-1CSXXA.
Indoor unit error display
O – light | X – off | ⊗ – flash |
Operation lamp | Timer lamp | Display | LED STATUS |
1 time | X | E0 | Indoor unit EEPROM parameter error |
2 times | X | E1 | Indoor / outdoor units communication error |
3 times | X | E2 | Zero-crossing signal detection error |
4 times | X | E3 | Indoor fan speed has been out of control |
5 times | X | E4 | Indoor room temperature sensor T1 open circuit or short circuit |
6 times | X | E5 | Evaporator coil temperature sensor T2 open circuit or short circuit |
7 times | X | EC | Refrigerant leakage detection |
1 time | O | F0 | Overload current protection |
2 times | O | F1 | Outdoor ambient temperature sensor T4 open circuit or short circuit |
3 times | O | F2 | Condenser coil temperature sensor T3 open circuit or short circuit |
4 times | O | F3 | Compressor discharge temperature sensor T5 open circuit or short circuit |
5 times | O | F4 | Outdoor unit EEPROM parameter error |
6 times | O | F5 | Outdoor fan speed has been out of control |
1 time | ⊗ | P0 | IPM malfunction or IGBT over-strong current protection |
2 times | ⊗ | P1 | Over voltage or over low voltage protection |
3 times | ⊗ | P2 | High temperature protection of IPM module or compressor |
4 times | ⊗ | P3* | Outdoor ambient temperature too low |
5 times | ⊗ | P4 | Inverter compressor drive error |
6 times | ⊗ | P5 | Indoor units mode conflict (multi-zone ONLY) |
* P3
1. In heating mode, when the outdoor temperature is lower than -13°F (-25℃) for 1 hour, the indoor unit display error code P3.
2. If the outdoor temperature is higher than -7.6°F (-22℃) for 10 minutes and compressor stop for 1 hour or outdoor temperature is higher than 23°F (-5℃) for 10 minutes, then the unit will return to work.
Outdoor unit error display
O – light | X – off | ⊗ – LED flashes at 2.5 Hz (5 flashes every 2 seconds) |
No. | Problems | LED3 (Green) | LED2 (Red) | IU display |
1 | Standby for normal | O | X | |
2 | Operation normal | X | O | |
3 | IPM malfunction or IGBT over-strong current protection | ⊗ | X | P0 |
4 | Over voltage or too low voltage protection | O | O | P1 |
5 | EEPROM parameter error | O | ⊗ | E5 |
6 | Inverter compressor drive error | X | ⊗ | P4 |
7 | Inverter compressor drive error | ⊗ | O | P4 |
8 | Inverter compressor drive error | ⊗ | ⊗ | P4 |
Explanation of error codes
E0 (indoor) / F4 (outdoor) Indoor or outdoor PCB main chip does not receive feedback from EEPROM chip.
E1 – Indoor unit does not receive the feedback from outdoor unit during 110 seconds and this condition happens four times continuously.
E2 – When PCB does not receive zero crossing signal feedback for 4 minutes or the zero crossing signal time interval is abnormal.
E3/F5 – When indoor fan speed is too low (300RPM) for certain time, the unit will stop and the LED will display the failure.
E4/E5/F1/F2/F3 – If the sampling voltage is lower than 0.06V or higher than 4.94V, the LED will display the failure.
EC – Define the initial evaporator coil temperature T2 when the compressor just starts running as Tcool. In the first 5 minutes after the compressor starts up in cooling mode, if T2<Tcool-2℃ (Tcool – 35.6℃) does not keep continuous 4 seconds and this situation happens 3 times, the display area will show “EC” and the unit will turn off . T2 sensor faulty – Indoor PCB faulty – System problems, such as leakage or blocking.
F0 – An abnormal current rise is detected by checking the specified current detection circuit.
P0 – When the voltage signal that IPM send to compressor drive chip is abnormal, the display LED will show “P0” and AC will turn off .
P1 – An abnormal voltage rise or drop is detected by checking the specified voltage detection circuit.
P2 – If the sampling voltage is not 5V, the LED will display the failure.
P4 – An abnormal inverter compressor drive is detected by a special detection circuit, including communication signal detection, voltage detection, compressor rotation speed signal detection and so on.