Models: GWH09QB-K3DNA1G , GWH09QB-K3DNA2G , GWH09QB-K3DNA5G , GWH09QB-K3DNB2G , GWH09QB-K3DNB4G , GWH09QB-K3DNB6G , GWH12QC-K3DNA1G , GWH12QC-K3DNA2G , GWH12QC-K3DNA5G , GWH12QC-K3DNB2G , GWH12QC-K3DNB4G , GWH12QC-K3DNB6G , GWH18QD-K3DNA1G , GWH18QD-K3DNA2G , GWH18QD-K3DNA5G , GWH18QD-K3DNA6G , GWH18QD-K3DNB2G , GWH18QD-K3DNB4G , GWH18QD-K3DNB6G , GWH18QD-K3DNB8G , GWH18QD-K3DNC2G , GWH24QE-K3DNA1G , GWH24QE-K3DNA2G , GWH24QE-K3DNA5G , GWH24QE-K3DNA6G , GWH24QE-K3DNB2G , GWH24QE-K3DNB4G , GWH24QE-K3DNB6G , GWH24QE-K3DNB8G , GWH24QE-K3DNC2G
E1 High pressure protection of system
E2 Antifreezing protection
E3 System block or refrigerant leakage
E4 High discharge temperature protection of compressor
E5 Overcurrent protection
E6 Communication Malfunction
E8 High temperature resistant protection
E9 Cold air prevention protection
EE EEPROM malfunction
EU Limit/ decrease frequency due to high temperature of module
C5 Malfunction protection of jumper cap
F0 Gathering refrigerant
F1 Indoor ambient temperature sensor is open/short
F2 Indoor evaporator temperature sensor is open/short circuited
F3 Outdoor ambient temperature sensor is open/short circuited
F4 Outdoor condenser temperature sensor is open/short circuited
F5 Outdoor discharge temperature sensor is open/short circuited
F6 Limit/ decrease frequency due to overload
F8 Decrease frequency due to overcurrent
F9 Decrease frequency due to high air discharge
FH Limit/ decrease frequency due to antifreezing
PH Voltage for DC bus-bar is too high
PL Voltage of DC bus-bar is too low
P0 Compressor Min frequence in test state
P1 Compressor rated frequence in test state
P2 Compressor maximum frequence in test state
P3 Compressor intermediate frequence in test state
P5 Overcurrent protection of phase current for compressor
PU Charging malfunction of capacitor
P7 Malfunction of module temperature sensor circuit
P8 Module high temperature protection
H3 Overload protection for compressor
H5 IPM protection – Module temperature is too high
H6 Internal motor (fan motor) do not operate
H7 Desynchronizing of compressor
HC PFC protection
L3 Outdoor DC fan motor malfunction
L9 power protection
LP Indoor unit and outdoor unit doesn’t match
LC Failure start-up
U1 Malfunction of phase current detection circuit for compressor
U3 Malfunction of voltage dropping for DC bus-bar
U5 Malfunction of complete units current detection
U7 The four-way valve is abnormal
U8 Malfunction of zero-cross detection circuit