Error codes – κωδικοί βλαβών κλιματιστικά AIRWELL
Indoor Units: AWSI-HZDE009-H11 , AWSI-HZDE012-H11 , AWSI-HZDE018-H11
Outdoor Units: AWAU-YBZE218-H11 , AWAU-YBZE324-H11 , AWAU-YBZE430-H11
Display |
Blinking
|
Blinking
|
Blinking
|
Fault description |
Reason |
---|---|---|---|---|---|
E1 |
1 |
HP switch protection |
Refrigerant was superabundant. Poor heat exchange (including blockage and bad radiating environment). Too high ambient temperature |
||
E2 |
2 |
Indoor coil defrost Protection |
Poor air-return in indoor unit. Fan speed is abnormal. Evaporator is dirty. |
||
E4 |
4 |
Compressor over Heating Protection |
Electronic Expansion Valve connection problem or damage. Refrigerant leakage. Poor heat exchange |
||
E5 |
5 |
AC Over current protection |
Supply voltage is unstable. Supply voltage is too low and load is too high |
||
E6 |
6 |
Communication malfunction |
Wiring mistakes Indoor Unit or Outdoor Unit PCB problem |
||
E7 |
7 |
Mode conflict |
Mode conflict to other Indoor Unit |
||
E8 |
8 |
Indoor , Outdoor coil over heating protection |
Too high ambient temperature. Poor heat exchange (including blockage and bad radiating environment) |
||
H6 |
11 |
No feedback of indoor motor |
IFAN motor damaged. IFAN motor blocked. Indoor Unit PCB problem |
||
C5 |
15 |
Malfunction protection of jumper cap |
Poor connection of the jumper on indoor PCB. |
||
U8 |
17 |
Zero-crossing protection (Indoor Unit) |
IFAN motor damaged. Zero-crossing circuit damaged on Indoor Unit PCB |
||
LP |
19 |
Mismatch of Indoor Unit and Outdoor Unit |
|||
F1 |
1 |
RAT failure |
Sensor was broken or damaged. PCB temperature detection circuit has problem |
||
F2 |
2 |
Indoor Coil Temperature (RT2) sensor failure |
Sensor was broken or damaged. PCB temperature detection circuit has problem |
||
F3 |
3 |
Outdoor Air Temperature sensor failure |
Sensor was broken or damaged. PCB temperature detection circuit has problem |
||
F5 |
5 |
Compressor Top Temperature sensor failure |
Sensor was broken or damaged. PCB temperature detection circuit has problem |
||
PH |
11 |
DC over voltage |
AC input voltage is too high. Reactor has problem. Outdoor Unit PCB has problem |
||
F4 |
18 |
Outdoor Coil Temperature sensor failure |
Sensor was broken or damaged. PCB temperature detection circuit has problem |
||
b5 |
19 |
RLT failure |
Sensor was broken or damaged. PCB temperature detection circuit has problem |
||
b7 |
22 |
Return Gas Temperature sensor failure |
Sensor was broken or damaged. PCB temperature detection circuit has problem |
||
H3 |
3 |
Compressor overload
|
Electronic Expansion Valve connection problem or damaged. Refrigerant leakage. OLP damaged |
||
H5 |
5 |
IPM protection |
Abnormal power input voltage. Compressor wiring mistake. Liquid and gas valve are not open. Electronic Expansion Valve damaged or not proper working. Poor heat exchange. Over charged system. |
||
HC |
6 |
Power Factor Corrector protection |
PFC module assembly problem. Poor heat exchange of Heatsink Power Factor Corrector reactor problem. Abnormal power voltage. Power Factor Corrector circuit problem on PCB |
||
H7 |
7 |
Desynchronizing of
|
Abnormal power input voltage. Compressor wiring mistake. Liquid and gas valve are not open. Electronic Expansion Valve damaged or not proper working. Poor heat exchange. Over charged system. |
||
Lc |
11 |
Compressor start up failure |
Compressor wiring mistake. Over charged system. System not balanced before compressor starting. Compressor problem |
||
U1 |
12 |
Compressor phase current detection problem |
Phase current detection circuit for compressor has problem. |
||
P5 |
15 |
DC over current |
Abnormal power input voltage. Compressor wiring mistake. Liquid and gas valve are not open. Electronic Expansion Valve damaged or not proper working Poor heat exchange. Over charged system. |
||
PU |
17 |
Charging malfunction of capacitor |
Reactor open. Charging relay or other components damaged on PCB. |
||
P7 |
18 |
Heat Sink Temperature sensor failure |
Sensor was broken or damaged. PCB temperature detection circuit has problem |
||
P8 |
19 |
Heat Sink Temperature sensor over heating protection |
Insufficient attachment of IPM module to Heatsink. Outdoor PCB problem. |
||
PL |
21 |
DC under voltage |
AC input voltage is too low. Reactor has problem. Outdoor Unit PCB has problem |
||
Ld |
Lack Phase Protection of Compressor |
Compressor wiring problem. Compressor problem. IPM module problem or compressor current detection circuit has problem. Compressor malfunction due to Electronic Expansion Valve problem |
|||